Power Your World With ZTA Diesel Generators-Customized,Reliable And Lifetime Support
Home Diesel Generator Set Perkins Diesel Generator

Big Power Generator 2000KVA Powered By Perkins 4016TAG2A

2000kva Perkins Power Generator

Big Power Generator 2000KVA Powered By Perkins 4016TAG2A

Perkins Diesel Generator Set


The Perkins Diesel Generator Set, manufactured by Perkins Engines Company Limited, is a power generation solution widely utilized across various industries. Operating on diesel fuel, it converts chemical energy into mechanical energy via a Perkins diesel engine, which is then transformed into electrical energy output through an integrated generator. Renowned for reliability, efficiency, and adaptability, these generator sets are engineered to meet diverse power demands, from emergency backup to continuous prime power applications.

  • Brand:

    Perkins
  • Item NO.:

    ZP2750
  • Order(MOQ):

    1
  • Payment:

    T/T 30%, 70% Before shipment
  • Price Range:

    230000 - 250000/$1
  • Product Origin:

    China
  • Shipping Port:

    Xiamen, China
  • Lead Time:

    2-4 weeks
  • Weight:

    12800

 

Perkins 4016TAG2A 1600 kW Diesel Generator Set


The Perkins 4016TAG2A, an imported 1600 kW diesel generator set from the UK, is a large-scale power generation solution designed to meet high-demand power supply requirements. Utilizing advanced technology from Perkins Engines Company, this unit delivers high-efficiency performance, exceptional reliability, and low-maintenance operation, ensuring stable power output even in extreme environmental conditions.

 

Prime Power (kw/kva) 1600kw/2000kva
Standby Power(kw/kva) 1760kw/2200kva
Frequency 50hz/1500rpm
Power Factor 0.8
Open Genset Size (L×W×H) mm 6200×2230 ×2650
Silent Genset Size (L×W×H) mm 12192×2438×2896(Standard 40ft HQ Container)

 

Perkins 4016-TAG2A

 

The PERKINS ENGINE

Integrates cutting-edge European and American technologies with high-strength wear-resistant materials, ensuring top-tier quality. Paired with the Leroy-Somer generator (produced by Emerson, a global industrial leader), the system delivers a compact design and exceptional efficiency. Rigorously tested with advanced computer-aided systems, it meets European and American technical standards 

Perkins Engine Model 4016TAG2A
Cylinder 16
Bore×Stroke(mm) 160×190
Displacement 61.123L
Aspiration

 Turbocharged and air to air charge cooled  

Fuel Consumption @ 100% Load 209L/h

 

Leroy somer Alternator Standard Configuration

     
  • Three-phase four-wire output with neutral point grounding.

  • Voltage: 380V/220V | Frequency: 50Hz/60Hz | Power Factor: 0.8 lagging.

  • Protection: Compliant with NEMA 1 and IP22 standards for dust and water resistance.

Leroy somer Model LSA52.3S6
AVR Standard  D510C(AREP+PMI)
Voltage Available 480/277V, 400/230V, 380/220V,220/127V
Insulation Class H
Number of Wires 12
Protection IP 23

 

Control Panel

 

UK Deepsea 6120,Smartgen 6120,Comap AMF 25,Deif Brand ... ETC Also Available Base on Customer Need

  Deepsea 6120 Deepsea 7320
Display Language 18 18
USB communication √  √ 
CAN port √  √ 
Event Log 100 250
Overspeed protection √  √ 
Low oil pressure protection √  √ 
High coolant temperature protection
Low fuel level alarm

 

Circuit Breaker

 

Brand   Xiakong
Type 3P
Amper 3200A

 

40FT HQ Soundproof Container 2000kva

 

Technical Support / Troubleshooting Methods/Procedures

 

Generator Fails to Start
Symptoms: Starter motor does not engage or disengages prematurely.
  • Possible Causes:

    1. Low battery voltage or insufficient charge.

    2. Starter motor failure.

    3. Starter motor misalignment.

    4. Intermediate relay short circuit (blown fuse).

  • Solutions:

    1. Check battery terminals for corrosion/loose connections.

    2. Repair/replace the starter motor.

    3. Manually crank the engine and retry.

    4. Replace the intermediate relay.


Engine Cranks but Fails to Ignite Possible Causes:
  1. No fuel supply to injectors.

  2. Air in fuel lines.

  3. Contaminated/watery fuel.

  4. Fuel pump failure.

  5. Incorrect injector timing.

Solutions:

Check fuel tank level and valves.

    1. Bleed air from fuel lines and inspect for leaks.

    2. Replace fuel filters.

    3. Repair/replace the fuel pump.

    4. Recalibrate injector timing.


Engine Stalls or Backfires After Ignition

Possible Causes:

  1. Fuel delivery issues.

  2. Faulty fuel pump.

  3. Clogged fuel/air filters.

  4. Cold engine (no pre-heat).

  5. Faulty injectors.

  6. Incorrect valve clearance.

Solutions:

  • Inspect fuel lines and bleed air.

  • Test/replace fuel pump.

  • Clean/replace fuel and air filters.

  • Check engine pre-heater (if equipped).

  • Replace injectors.

  • Adjust valve clearance.


General Engine Troubleshooting

  • Critical Steps:

    1. Identify pre-failure symptoms (e.g., warnings, recent maintenance).

    2. Check simple causes first (e.g., loose throttle linkage, clogged filters).

    3. Refer to the Appendix: Fault Diagnosis Table and engine service manual.

  • Examples:

    • Low Power: Often caused by dirty filters or loose throttle mechanisms.

    • Excessive Oil Consumption: Check for leaks at seals/pipe joints.

Generator Set Contact

 

 

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

20kva Perkins Diesel Generator
EPA Tier 3 Certified 20kVA 16kw Perkins 404D-22G Engine

The Perkins 404D-22G diesel generator delivers 16kW (20kVA) of reliable prime power in a compact, fuel-efficient package. With EPA Tier 3 emissions certification

Details
520kW Perkins diesel generator
Prime Power Generator 520kw 650kVA Perkins 2806A-E18TAG2 Engine

The Perkins 2806A-E18TAG2 diesel generator delivers 520kW (650kVA) of prime power, designed for continuous, heavy-duty operation in demanding environments

Details
15kVA Perkins diesel generator
15kVA Perkins 403A-15G2 Diesel Generator

The Cummins 6CTA8.3-G2 diesel generator delivers 150kW (188kVA) of robust prime and standby power for mission-critical applications

Details
10kva Perkins Diesel Generator
Diesel Generator 10KVA Perkins 403D-11G

The Perkins Generator Set combines robust engineering with exceptional reliability, delivering high-performance power solutions for industrial, commercial, and emergency applications. Powered by Perkins’ renowned diesel engines, these generator sets are designed for fuel efficiency, durability, and compliance with global emission standards (e.g., Tier 4 Final)

Details
Perkins 120kW Generator
Perkins 120KW 150kVA Open Silent Generator 1106A-70TAG2

ZTA Power Perkins 150kVA Diesel Genset Powered With Perkins 1106A-70TAG2 and Brushless Alternator

Details
150kW Cummins diesel generator
150kw 188kva Cummins 6CTA8.3-G2 Diesel Generator Set

The Cummins 6CTA8.3-G2 diesel generator delivers 150kW (188kVA) of robust prime and standby power for mission-critical applications

Details
25kva Diesel Generator
Cummins Diesel Generator 25KVA 4B3.9-G2

20kW 25kva Cummins Diesel Generator Set The 20kW Cummins Diesel Generator Set delivers reliable, high-performance power for residential, commercial, and industrial applications. Engineered with Cummins' proven diesel technology, it ensures fuel efficiency, low emissions, and extended durability.  

Details
10kva Mobile Lighting Tower
Prime Power 10kva Mobile Lighting Tower Power By Perkins Engine

The Lighting Tower not only provides stable power supply for the lighthouse but also ensures its normal functioning during severe weather conditions.

Details

Subscribe to Our Newsletter

Sign up for our monthly promotion and get out latest product news!

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
Contact Us:nancy@ztapower.com

Home

Products

whatsapp

contact