ZTA POWER 6kW diesel mobile light tower is a towable lighting unit integrated with a 5.5kW diesel genset. Equipped with a height-adjustable telescopic mast and 4 LED floodlights, it delivers stable, high-brightness illumination. Ideal for construction sites, road maintenance, mining works and emergency rescue. Compact trailer design, easy to tow and operate.
Brand:
ZTAItem NO.:
ZLTS4005Order(MOQ):
1Payment:
T/T 30%, 70% Before shipmentProduct Origin:
ChinaShipping Port:
Xiamen, ChinaLead Time:
3-4weeksWeight:
18840
7 m telescopic mast · 4 × 400 W LED floodlights · ≈70 h on one tank · 540 kg towable trailer
The ZLTS4005 is a single-axle diesel light tower that carries its own power. A 6 kW (6 kVA) air-cooled diesel generator set, a five-section mast that reaches 7 metres and four LED floodlights giving 192,000 lumens — mounted on one trailer that one pickup can tow. No cable, no temporary supply, no site permission: park it, level the legs, winch up the mast and the site is lit.
Designed for construction, quarry and rental fleets, it runs a full night shift on a 120 L tank and still leaves more than 4 kW of spare capacity for hand tools, a site office or a small distribution board.

A light tower is not a lamp on a pole — it is a small diesel generating set, a mast and a lighting rig sharing one chassis. Everything the tower does starts with the genset: how long it runs, how much load it can carry and how it behaves on a dusty site.
Inside the ZLTS4005 canopy, a single-cylinder ZTA POWER 188 air-cooled diesel engine drives a brush self-excited alternator. The set delivers 6 kW at power factor 1, at 50 Hz or 60 Hz, with output adjustable from 110 V to 270 V to match the destination market. Lighting takes 1.6 kW of that; the remaining capacity is available at the outlet for tools and small equipment — which is exactly the difference between a lighting tower and a lamp.
| Generator set — ZLTS4005 technical data | |
|---|---|
| Model | ZLTS4005 |
| Rated power / standby | 6 kW / 6 kVA |
| Voltage | 110–270 V available (set to destination market) |
| Frequency / phase | 50 Hz or 60 Hz / single phase |
| Power factor | 1 |
| Starting | Electric start, 12 V battery |
| Control panel | SmartGen 5 controller, digital hour meter, live monitoring |
| Canopy protection | IP65 |
| Fuel tank / runtime | 120 L polyethylene tank / ≈70 h |
| Dimensions (mast extended) | 2,804 × 2,564 × 7,500 mm |
| Weight | 540 kg |
Figures above are the series specification. Final voltage, frequency and socket configuration are confirmed on the order drawing.
Light towers live outdoors. They are started at dusk, run unattended through the night and are parked in dust, rain and heat. The single-cylinder 188 engine is the specification that survives that routine: direct injection, air cooling, mechanical governing and very little to go wrong.
With no cooling circuit there is no coolant level to check and no radiator to clog with dust. The engine reaches working temperature quickly, which matters when a tower is started and stopped several times a night on a rental contract.
| Engine data | |
|---|---|
| Engine brand / model | ZTA POWER 188, diesel |
| Configuration | Single cylinder, four-stroke, direct injection |
| Cooling | Air-cooled |
| Bore × stroke | 88 × 90 mm |
| Displacement | ≈0.55 L |
| Rated speed | 3,000 rpm at 50 Hz / 3,600 rpm at 60 Hz |
| Fuel consumption | ≈1.7 L/h at rated lighting load (derived from 120 L / ≈70 h) |
| Starting | Electric, 12 V |
Fuel consumption varies with load, ambient temperature and lamp configuration. The ≈70 h figure is measured at continuous lighting duty.
The brush self-excited alternator keeps the voltage steady as the floodlights switch on and off, and it is deliberately simple: no external excitation board to fail in damp conditions. Output is single phase with power factor 1, factory-set to the voltage and frequency your market uses.
| Alternator, control & protection | |
|---|---|
| Alternator power | 6 kW / 6 kVA |
| Phase / output | Single phase, 220 V AC standard (other voltages to order) |
| Excitation | Brush, self-excited |
| Frequency / voltage | 50 Hz or 60 Hz / 110–270 V available |
| Controller | SmartGen 5, digital display, hour meter, running monitoring |
| Battery | 12 V |
| Enclosure rating | IP65 canopy with lockable service access |
Each of the four lamp heads produces 48,000 lumens, so the tower puts 192,000 lumens on the ground — enough to light a work face, a loading bay or a night-time road repair with even, white light. LED heads strike instantly at any temperature, draw only 400 W each and do not need the warm-up a metal-halide lamp does.
The mast is five telescopic sections raised by a manual winch: no hydraulic circuit, no pump to service, and one operator can raise or lower it in a few minutes. The head rotates a full 360°, so a single tower can serve two working areas during a shift.
| Mast & lighting data | |
|---|---|
| Floodlights | 4 × 400 W LED, flood beam |
| Light output | 4 × 48,000 lm = 192,000 lm total |
| Mast height | 7 m, telescopic, 5 sections |
| Rotation | 360° |
| Lifting | Manual winch, single operator |
| Wind resistance | Designed for sites exposed to 100 km/h gusts (mast lowered in storm conditions) |
| Warning light | Yes, fitted for night transport and site marking |
Every unit follows the same route through our Xiamen facility. Nothing is sub-assembled and left untested; each stage is signed off before the next one starts, and the completed tower is load-tested before it is packed.
Canopy panels, chassis beams and mast sections are cut from steel sheet and tube on CNC equipment, then deburred and marked for traceability.
Panels are folded on press brakes, the chassis is welded on fixtures to keep it square, then the whole assembly is shot-blasted and powder-coated in ZTA orange and graphite.
The engine and alternator are mounted on a common bed, coupled and aligned, then torqued to specification so vibration stays low at 3,000/3,600 rpm.
Wiring is routed and loomed, the SmartGen 5 controller, hour meter, sockets and breakers are fitted, and every circuit is point-to-point checked against the drawing.
Mast sections, winch, cable guide and the four-head lighting yoke are fitted; the mast is raised and lowered repeatedly to check travel and cable routing.
Axle, wheels, drawbar, jockey wheel, stabiliser legs and safety chains are fitted, and the unit is levelled on its four legs to confirm stability with the mast up.
The set is run on a resistive load bank, lamps are burned in, and output voltage, frequency, insulation resistance and earthing are recorded on the test sheet.
Paint, labels, manuals and decals are checked, the mast is retracted and locked, and the unit is wrapped for container loading with its test record.
Fabrication, assembly and testing sit under one roof, which is why we can quote a light tower, a bespoke voltage and a container quantity in one reply — and why a spare part still fits a unit built years earlier.
Standard lead time: within 30 days after receipt of deposit. Delivery terms EXW Xiamen by default; FOB and CIF quoted on request.
A 7 m mast does not fit in a 20' container, so the tower ships with the mast fully retracted and locked, the lamp yoke protected, and the trailer secured as a rolling unit. That is what makes six units fit a 20'GP and twenty-four fit a 40'HQ.
| Packing & loading | Detail |
|---|---|
| Mast in transport | Fully retracted, locked, lamp yoke folded and padded |
| Surface protection | Lamp heads and control panel wrapped, canopy corners protected |
| Unit packing | Stretch film and strapping; plywood case optional for LCL |
| Packed dimensions (approx.) | 2,800 × 800 × 2,300 mm, mast retracted |
| Net weight | 540 kg per unit (gross weight confirmed on packing list) |
| Documents in the box | Operation manual, test record, wiring diagram, warranty card |
| 20'GP | 6 units |
| 40'HQ | 24 units |
Loading is photographed and the container plan is sent before departure, so the receiving warehouse can match units to the packing list on arrival.
Xiamen ZTA Power System Co., Ltd designs and builds diesel generator sets and lighting towers in Xiamen, China, covering a power range from 10 kVA to 5,000 kVA alongside lighting towers, reefer gensets and genuine spare parts.
Because the genset, canopy, mast and trailer are built and assembled by the same team, a light tower enquiry is answered with one drawing and one test report — not a generator from one supplier matched to a mast from another. Voltage, frequency, socket layout, canopy colour and branding can all be set to the order.
Every unit ships with a 12-month / 1,000-hour warranty, a test record and a spare parts channel that keeps the same part numbers year after year.
One tower lights a work face wide enough for plant and crews to operate safely after dark. Most fleets use it for night construction, but the same unit is specified for quarry faces, port loading areas, pipeline spreads, event sites and emergency response.
Both. The four floodlights draw 1.6 kW in total, leaving roughly 4.4 kW of the 6 kW rating available at the outlet for hand tools, a pump, a small compressor or a site office load.
A 120 L tank gives about 70 hours at continuous lighting load, which is close to a full week of 12-hour night shifts. Fuel consumption is approximately 1.7 L/h.
Six units in a 20'GP and twenty-four in a 40'HQ, with the mast retracted and the units loaded as rolling trailers. Mixed models can be consolidated in one container on request.
One unit for a sample order, and production within 30 days after receipt of the deposit. Repeat orders on the same drawing are scheduled faster.
Yes. The set is built for 50 Hz or 60 Hz and 110–270 V, with the socket and plug configuration specified on the order drawing — 220 V single phase being the standard build.
By a manual winch, deliberately: no hydraulic pump, hoses or rams to leak or service. One operator can raise the mast to 7 m in a few minutes.
The LED heads are modular and interchangeable, so a head can be swapped without removing the yoke assembly. Spare heads and mast cables are available as service parts.
12 months or 1,000 running hours, whichever comes first, covering the generator set and the tower assembly. Wear parts and lamp heads are covered against manufacturing defects.
Send us the voltage, frequency, quantity and destination port. You will get an EXW Xiamen quotation, a delivery schedule and a container loading plan in one reply.
Request a quotation See all lighting towers